Velacent Bridge: beta December 2026, general availability early 2027. E-mail sales to request beta access.

PowerServer (RamSoft)

HL7 v2 2.3.1 interface as documented publicly: ORU^R01, MFN^M02, ADT^A08, ADT^A40, ADT^A23, SQM^S25, ORM^O01, VXU^V04, BAR^P01, BAR^P05, DFT^P03, QRY^A19, and 6 more.

From public documentation — not verified by RamSoft

Vendor
RamSoft
Product
PowerServer
Versions it applies to
Document version 2.3.1, PowerServer 6, HL7 v2.3.1
Category
Diagnostic department information systems
Standard
HL7 v2
Message types
ORU, MFN, ADT, SQM, ORM, VXU, BAR, DFT, QRY, SIU, SQR, ADR
Direction
Send
Partner FHIR access
Cannot be queried (not stated)
Last checked
Vendor's documentation
RamSoft developer documentation

Built from RamSoft's public specification, https://www.ramsoft.com/hubfs/HL7%20Conformance_aug26.1.pdf, read ; not yet verified by RamSoft. It describes the interface the specification states and does not replace the vendor's own documentation or a test with the live system. RamSoft can claim this listing and publish its own verified profile.

Claim this listing for PowerServer (RamSoft) Publish your interface — no fee All connectors

More from RamSoft