Beta December 2026, general availability early 2027
Healthcare interoperability for everyone
Connect your hospital, clinical, laboratory, radiology, billing, clearinghouse and partner systems with published prices, a go-live measured in days, and nothing to install behind your firewall except one small connector.
250+ tested connectors from 200+ vendors, and a growing catalog.
- receivedORU^R01 from Lab systemReceived
- checkedHL7 v2.5.1 wire formatValid
- auditedAudit record writtenWritten
- matchedPatient found in the eMPILinked
- convertedHL7 v2 to FHIR R4Done
- deliveredEHR returned ACK AADelivered
- deliveredCloud FHIR store returned 201Delivered
Speaks the standards you already use
- HL7 v2 over MLLP and HTTPS
- FHIR R4
- C-CDA
- X12 837
- X12 835
- X12 270/271
- DICOM structured reports and documents
- SFTP batch files
- Database readers and writers
Hosting, scaling, security patching and audit included. Browse the connector catalog (250+ connectors) · Security and trust
How one message moves through Bridge
Follow one lab result from the lab system to the chart: connect, convert, match, deliver and prove.
-
1Connect
Connect the systems you already have
No VPN for on-premises systems. Velacent Ramp is a small service on one of your machines. It connects out over HTTPS on port 443, so there is no site-to-site tunnel to build.
HL7 v2 over MLLP and HTTPS, SFTP batch files, FHIR R4, database readers and writers. Unlimited Ramp connectors are included in every edition, inside routing, retries and audit.
- Lab systemHL7 v2 over MLLP, through Ramp on your networkConnected
- Clearinghouse dropX12 835 batch files over SFTPConnected
- Partner appFHIR R4 over HTTPSConnected
- Referral fax lineDocuments and fax add-onTesting
Illustrative preview with synthetic data. -
2Convert
Convert between the standards each system needs
HL7 v2 version conversion per destination, HL7 v2 to FHIR R4 following the HL7 v2-to-FHIR Implementation Guide, and C-CDA to FHIR and back.
HL7 v2.5.1 in
OBX|1|NM|2345-7^Glucose^LN|| 95|mg/dL|70-99|N|||F
FHIR R4 out
{ "resourceType": "Observation", "status": "final", "code": {"coding": [{ "system": "http://loinc.org", "code": "2345-7" }]}, "valueQuantity": { "value": 95, "unit": "mg/dL" } }Illustrative preview with synthetic data. -
3Match
One patient, one identity: a built-in eMPI
A built-in eMPI (enterprise master patient index) on every edition, with no per-patient fee.
Match patients across systems
Records from HL7 v2, FHIR, C-CDA and X12 are matched on the whole record: names with nicknames and misspellings, birth-date typos, address, phone, next of kin and every identifier, with each issuer resolved per sender.
Answer identity queries
IHE PIXm and PDQm over FHIR R4 and FHIR Patient $match. On Enterprise, connect the eMPI you already run over IHE PIX/PDQ, PIXm/PDQm or $match.
People decide the uncertain ones
Possible matches go to a review queue with the records side by side. Twins, Jr and Sr, and newborn placeholder names are never linked automatically, every automatic link can be undone, and every decision is audited.
FieldFrom Lab systemFrom EHRNameAlex SampleAlexander SampleBirth date1984-03-071984-07-03Phone555-0100555-0100Address12 Example St12 Example StreetBirth date may be a typo. A person decides.Illustrative preview with synthetic data. -
4Deliver
Deliver to every system that needs it
One message goes to every destination that should have it, formatted for each. Delivery retries until it succeeds, with a dead-letter queue and no message loss on restart.
- EHRHL7 v2.5.1, ACK code AADelivered
- Scheduling systemHL7 v2.3, converted for this destinationDelivered
- Lab systemConnection down, message kept and retriedRetrying
- Billing systemPatient identifiers cleaned for this destinationDelivered
Illustrative preview with synthetic data. -
5Prove
See every step, and fix what fails
Every action is audited, and if the audit record cannot be written the action does not happen.
Explain says why a message was rejected and how to fix it.
EHR returned ACK code AE for ORU^R01. Error in PID-3.
Explain
The lab sent this result without a medical record number in PID-3, so the EHR could not file it. Ask the lab to include the number, then replay the message.
Nothing changes until you confirm.Illustrative preview with synthetic data.
Built in, not bolted on
-
Documents and fax
Faxes and scanned documents become structured messages for your EHR, with the original attached and a review queue for anything uncertain. An add-on on any edition, priced per document.
- Patient
- Alex Sample
- Birth date
- 1984-03-07
- Reason
- Knee pain, 6 weeks
- Original
- Attached, 1 page
HL7 v2 ORMFHIR ServiceRequest1 field to review
Illustrative preview with a synthetic referral. -
AI that asks before it acts
The Help Agent answers by voice or text on any screen, Explain says why a message was rejected and how to fix it, and Ask AI answers questions about your own interfaces. Nothing changes until a person confirms it.
Illustrative question. -
Claims and eligibility
Claims to your own clearinghouse with acknowledgments and remittances tracked, eligibility checks routed back into your systems, and prior authorization over FHIR with your payer.
-
Networks
Query and answer national networks through your own participation: TEFCA through your QHIN, and eHealth Exchange and other IHE gateways.
-
Security you can check
Every action is audited, and if the audit record cannot be written the action does not happen. Patient data stays in US regions under a BAA. The security review pack answers the questionnaires and states plainly that we hold no third-party attestation yet.
-
For developers and vendors
A Data API with webhooks and a sandbox, FHIR access for linked vendors, configuration as code and a Terraform provider.
route.tf, from the Terraform provider documentation (example values, shortened) resource "velacent_route" "lab_results" { id = "lab-results" document = jsonencode({ priority = 10 match = ["ORU^R01"] destination = { kind = "mllp" address = "10.20.0.15:2575" } }) }
Start from the outcome
Say what should happen and which systems you have, and Bridge sets up the route, the conversion and the checklist. 3720 ready-made connections between 200+ systems (32 tested end to end in simulation; the rest built from the systems' published documentation).
Affordable, published prices
No per-interface fees, no onboarding fee, no per-connector fee.
-
Starter
$399 / month
Launch offer: $299 / month for customers who sign up on or before 2027-06-30, locked for their first 12 months, then $399 / month. $399 is the price new customers pay once the offer ends
-
Pro
$3,000 / month
-
Enterprise
$15,000 / month
Enterprise: 12-month term, billed annually up front (quarterly on request), by Google Cloud Marketplace private offer; no onboarding fee.
See every priceFree for 14 days or until the Google trial credit is used, whichever comes first. Start from Google Cloud Marketplace.
Designed to go live in under 14 days
Sign up through Google Cloud Marketplace, follow the Get started checklist, send a test message and go live with go-live checks. The free trial lasts 14 days so you can prove it first.
Migrate from your current engine
Import from Mirth Connect and Open Integration Engine, Rhapsody, InterSystems (HealthShare, Health Connect, IRIS for Health, Ensemble), Cloverleaf, Iguana, Corepoint Integration Engine, Qvera Interface Engine (QIE), Oracle Health (Cerner / Siemens) OPENLink, Microsoft BizTalk Server (with the HL7 accelerator), Oracle SOA Suite and Java CAPS (eGate), then run both side by side and compare field by field before you cut over.
Try it with your own messages
Start the free trial from Google Cloud Marketplace. When it ends, your plan continues in place with everything you set up; cancel before the end if you decide not to keep it.